ICH AI Detection Pipeline

End-to-end intracranial hemorrhage (ICH) detection: MaxViT classifier + agentic radiology workflow + browser worklist + DICOM Structured Report

This repository contains a complete research demonstration of an AI-assisted ICH screening pipeline built on the RSNA Intracranial Hemorrhage Detection dataset. It includes the calibrated CT preprocessing method that underpins the model, the trained MaxViT classifier, and a fully operational agentic pipeline that processes DICOM CT head studies and surfaces results on a browser-based radiology worklist.


The training dataset (RSNA Intracranial Hemorrhage Detection, Kaggle 2019) is not included and must be downloaded separately. The demonstration CT studies are sourced from the CQ500 dataset (qure.ai, CC-BY-NC-SA 4.0). The trained model checkpoint is hosted on HuggingFace Hub — see Demo for download instructions.


Table of Contents

  1. Pipeline Overview
  2. Demo
  3. Agentic Mode — Anthropic API
  4. Model Performance
  5. HU Density Overlay
  6. Understanding the Statistics — A Bayesian Perspective
  7. When to Trust the AI — and When Not To
  8. Repository Structure
  9. Calibrated CT Preprocessing
  10. Credits and Acknowledgements

Pipeline Overview

DICOM study folder
        │
        ▼
  scan_study()          ← reads all series headers (no pixel data)
        │
        ▼
  series selection      ← identifies axial noncontrast CT head sequence
        │
        ▼
  run_ich_inference()   ← MaxViT-Base (118 M params, 6-class multi-label)
        │                  per-slice probabilities → study-level aggregation
        ▼
  generate_dicom_sr()   ← DICOM Comprehensive SR with real test-set metrics
        │                  (AUC, Sens, Spec, LR+, LR−, PPV, NPV, Pain Index)
        ▼
  flag_worklist()       ← priority flag if ICH detected
        │
        ▼
  Browser worklist      ← CT slice viewer + SR panel + probability bars

All five subtypes are detected independently: epidural · intraparenchymal · intraventricular · subarachnoid · subdural


Demo

Quick start

# 1. Clone the repository
git clone https://github.com/rayolddog/ich-maxvit.git
cd ich-maxvit

# 2. Install dependencies
pip install -r requirements.txt

# 3. Download the trained checkpoint (1.4 GB, one time only)
python download_checkpoint.py

# 4. Run the pipeline — processes all 10 demo studies (~16 s on GPU)
python run_demo_direct.py

# 5. Start the worklist server
python ich_worklist.py
# Open http://localhost:5050 in a browser

A CUDA GPU is recommended for step 4. Apple Silicon (MPS) and CPU are supported — CPU inference takes a few minutes rather than seconds.


Step-by-step details

1 — Install dependencies

All required packages are listed in requirements.txt:

pip install -r requirements.txt

A virtual environment is recommended:

python3 -m venv .venv
source .venv/bin/activate   # Windows: .venv\Scripts\activate
pip install -r requirements.txt

2 — Download the trained checkpoint

The model checkpoint (best_maxvit_ich.pth, 1.4 GB) is hosted on HuggingFace Hub and is not included in this repository (too large for GitHub).

python download_checkpoint.py

This saves the file to checkpoints_maxvit/best_maxvit_ich.pth. Run once after cloning; it is not needed again unless the folder is deleted.

3 — Demo studies

Ten anonymised CT head studies are included in demo_studies/ (five positive — one of each hemorrhage subtype — plus five negative controls).

Note: demo_studies/ is currently excluded pending permission from the RSNA Educational Division to redistribute the anonymised DICOM subset. If the folder is absent, rebuild it from the full RSNA dataset:

python build_demo_studies.py \
    --dicom-dir /path/to/rsna/stage_2_train \
    --labels-csv /path/to/stage_2_train.csv \
    --out demo_studies

4 — Run the pipeline

python run_demo_direct.py

Processes all 10 studies without an API key. For each study: reads DICOM headers, selects the axial noncontrast series, runs MaxViT inference, generates a DICOM SR, and populates the worklist. Takes ~16 seconds on GPU.

5 — Start the worklist server

python ich_worklist.py
# Open http://localhost:5050 in a browser

Browser compatibility: Use Firefox or Microsoft Edge. Google Chrome blocks connections to localhost ports on some platforms and may refuse to load the page.

The worklist lists all studies with AI-positive cases flagged at the top. Click any patient name to open the CT viewer. The viewer shows the highest-scoring CT slice, per-subtype probability bars, Bayesian performance metrics, and a formatted report paragraph ready to paste into dictation software (PowerScribe or equivalent). Use the arrow keys to step through hot slices. Toggle HU Overlay to highlight tissue in the 48–90 HU acute hemorrhage density range.

Run the pipeline — with Anthropic API key (optional)

export ANTHROPIC_API_KEY="sk-ant-api03-..."
python run_demo_agent.py

See Agentic Mode below.


Agentic Mode — Anthropic API

What changes with an API key

run_demo_direct.py calls the inference tools directly and fills the radiology report with templated text. run_demo_agent.py instead routes every study through a Claude Opus agent that:

Step Direct mode Agentic mode
Series selection Rule-based (modality = CT, no contrast, thinnest slice) Claude reads all series metadata and reasons about which sequence best meets NCCT head criteria
Report paragraph Fixed template filled with model output Claude writes a contextualised radiology report paragraph using precise anatomical terminology, PPV/NPV at the specific assumed prevalence, and slice-level localisation
Impression bullet Fixed template Claude writes a concise impression tailored to the clinical indication
Negative reports Generic NPV statement Claude acknowledges the indication, explains the NPV at assumed prevalence, and notes any borderline findings

For the demo the templated reports are accurate and complete. In a production or research setting aimed at radiologists, the Claude-written reports are substantially more informative — particularly for positive studies where the finding description, anatomical localisation, and clinical context matter.

When is the API called?

The Claude agent orchestrates the entire pipeline for every study, positive and negative alike. It must call scan_study, select a series, call run_ich_inference, call generate_dicom_sr, and write the final report regardless of the result. A negative study produces a shorter report but still passes through the agent.

An architectural optimisation — running direct-mode inference first and only invoking the agent for positive studies — would reduce API cost by approximately the fraction of studies that are positive (typically 5–15% in an ED setting). This optimisation is not implemented in the current demo but would be the natural next step for a production deployment.

Getting an API key

The Anthropic API is billed separately from Claude.ai subscriptions (including Claude Pro). There is no required monthly subscription tier — the account is pay-as-you-go.

  1. Go to console.anthropic.com
  2. Create an API account and add a payment method
  3. Purchase credits (minimum ~$5)
  4. Generate an API key under API Keys

Estimated cost

The agent uses claude-opus-4-6 (Claude Opus). Each study requires approximately four API round-trips (scan → inference → SR → report), consuming roughly:

Token type Per study Rate (claude-opus-4-6) Cost per study
Input ~3,000 tokens $15 / 1M tokens ~$0.045
Output ~700 tokens $75 / 1M tokens ~$0.053
Total ~$0.10
Scenario Studies Estimated cost
10-study demo 10 ~$1.00
Typical ED day 50 ~$5.00
Busy week 250 ~$25.00

Switching from claude-opus-4-6 to claude-sonnet-4-6 in ich_agent.py reduces cost roughly 5× while still producing high-quality reports.


Model Performance

MaxViT-Base trained from random weights on the RSNA ICH dataset. Evaluated on the held-out test set (200,000 slices, never seen during training).

Class Prevalence AUC Sensitivity Specificity LR+ LR− PPV* NPV*
Epidural 0.42% 0.985 0.939 0.944 16.76 0.065 11.8% 99.97%
Intraparenchymal 4.85% 0.989 0.944 0.944 16.93 0.059 46.3% 99.7%
Intraventricular 3.52% 0.988 0.940 0.941 15.91 0.064 37.0% 99.8%
Subarachnoid 4.79% 0.983 0.946 0.941 16.07 0.057 45.1% 99.7%
Subdural 6.33% 0.984 0.934 0.944 16.66 0.070 53.1% 99.5%
Any ICH 14.49% 0.986 0.940 0.945 17.18 0.064 74.0% 99.1%

* PPV and NPV computed at the test-set prevalence shown. These values change with the local prevalence of the imaging population — the DICOM SR and worklist viewer recalculate them dynamically.

Thresholds chosen by Youden J (maximising sensitivity + specificity — a clinically sensible operating point for a screening test where missed ICH is far more costly than a false alarm).


HU Density Overlay

The CT slice viewer includes an HU Overlay toggle button that tints pixels red wherever tissue density falls in the Hounsfield unit range expected for acute intracranial hemorrhage (48–90 HU). This overlay is computed directly from the raw DICOM pixel data — it is entirely independent of the AI model and represents a physics-based measurement rather than a learned inference.

This overlay is not an AI activation map

The HU overlay is computed entirely from raw DICOM pixel values using a fixed density threshold. It has no connection to the neural network's internal representations. It does not show where the AI detected hemorrhage, and it does not confirm or explain the AI result. Its sole purpose is to direct the radiologist's attention to areas of unexpected high density during review.

What the red pixels represent

Acute blood has a characteristic density of approximately 50–80 HU on noncontrast CT, arising from the protein content of haemoglobin. The overlay uses the range 48–90 HU, consistent with the narrow window used during model training, to capture the full range of acute and hyperacute clot densities.

What the overlay will not highlight — chronic subdural hematoma

Chronic subdural hematomas (typically ≥ 1 week old) undergo lysis and progressive protein breakdown. Their density falls progressively from the acute range (~60–80 HU) toward isodensity with brain parenchyma (~30–40 HU) and eventually toward CSF density (~0–15 HU) in the chronic-liquefied stage. By the time a subdural is considered chronic, it is largely or entirely below the 48–90 HU threshold and will not be highlighted by the overlay.

This is clinically important: if the AI flags a study as positive for subdural hematoma and the overlay shows no red pixels in the expected extra-axial location, the most likely explanation is a chronic or subacute subdural — not a false positive. The AI model was trained on the full RSNA dataset which includes chronic subdurals; the HU overlay was not. These are two different tools measuring different things.

Chronic subdural hematomas, while generally less immediately life-threatening than acute hemorrhage, still require clinical management and should not be dismissed because the overlay is unremarkable.

What else the overlay highlights — expected normal findings

Because the threshold is purely density-based, the overlay will also mark structures that are entirely normal and should be mentally subtracted:

  • Partial volume averaging at the inner table of the skull — the most prominent normal finding: a bright ring around the brain edge where cortical bone averages with adjacent soft tissue.
  • Metal implants and artifact — surgical clips, shunt hardware, and dental or cervical spine metal produce streak artifacts that cross this HU range.
  • Physiological calcifications — choroid plexus, pineal gland, habenular commissure, and basal ganglia calcifications commonly fall in this range.
  • Beam hardening streaks — dense bone and metal occasionally produce adjacent streaks reaching this density range.

Why it is still clinically useful

An experienced radiologist immediately recognises the normal high-density structures listed above. The signal of clinical interest is unexpected red pixels in the parenchyma or extra-axial space — away from bone edges, known calcification sites, and metal artifacts.

The overlay provides a rapid pre-attentive cue: is there material in the hemorrhage density range where there should not be?

The overlay is complementary to the AI model rather than redundant. The model learned statistical patterns across hundreds of thousands of CT slices; the HU overlay is raw physics. When the AI flags a slice and the overlay shows unexpected high-density pixels in the same region, that is two independent lines of evidence pointing to the same finding — which is reassuring. When the AI flags a slice for acute hemorrhage but the overlay shows nothing unusual at that location, chronic or subacute hemorrhage should be the leading consideration.

The overlay is not a segmentation tool and has not been validated against radiologist-drawn regions of interest. It is a display aid intended to direct attention, not to replace clinical judgment.

Where the overlay is most and least useful

The HU overlay is most informative for subarachnoid, intraparenchymal, and intraventricular hemorrhage, where acute blood appears in locations that are clearly distinct from the normal high-density structures described above. Unexpected red pixels in the sulci, within the parenchyma, or lining the ventricular walls are immediately recognisable as abnormal.

The overlay is least reliable for extracerebral hematomas (subdural and epidural), for reasons beyond the chronic subdural density shift already discussed. Partial volume averaging at the inner table of the skull produces a red rim that can mask or mimic an adjacent thin extracerebral collection. An important exception: in some cases of chronic or subacute subdural hematoma, the edges of the collection may still be highlighted even when the bulk of the fluid is isodense. This occurs because the interface between the displaced inner cortical surface of the brain and the overlying hyperdense membrane — a thin split visible between the skull edge and the inwardly displaced brain margin — may fall within the 48–90 HU range. Whether this edge effect is visible depends heavily on the reconstruction algorithm: higher spatial frequency (detail or bone) kernels produce overshoot at tissue interfaces through edge enhancement, making the split more apparent; softer reconstruction kernels suppress it. This sign is therefore inconsistent and should not be relied upon as a primary finding.

Learning curve

Just as radiologists must learn to interpret the marks placed on mammograms by AI-assisted breast cancer detection systems, there is a learning curve in using the HU overlay effectively. The key skill is rapid mental subtraction of the expected normal findings — the skull rim, calcifications, and any artifact — to isolate the residual signal. With experience, the overlay becomes a fast pre-attentive check rather than a source of uncertainty.

Future direction

The current implementation uses a fixed HU threshold applied uniformly across the image. This is intentionally simple — straightforward to implement, deterministic, and grounded in established CT physics. More advanced approaches using learned segmentation models (such as a MaxViT-based architecture trained on radiologist-annotated regions) could provide more anatomically precise localisation, separating true hemorrhage from normal high-density structures with far greater specificity. The HU overlay represents a practical first step; the path to improvement is clear.


Understanding the Statistics — A Bayesian Perspective

The AI model is basically a sophisticated algorithm that detects structures in images and tests whether those structures match how acute intracranial hemorrhage appears on CT scans. The model is effective at determining whether a detected structure is likely to represent an area of hemorrhage. Because of extensive training on noncontrast CT images of the head, it is possible to determine how likely a finding represents intracranial hemorrhage.

The likelihood that a given structure represents hemorrhage is expressed by the Bayesian inference statistics of likelihood ratio, prevalence of disease, and positive and negative predictive value. The most important results are the two statistics: Positive Predictive Value (PPV) and Negative Predictive Value (NPV).

Because of the low prevalence of intracranial hemorrhage in the general patient population undergoing head CT, even a powerful test will likely result in fewer than 30% of AI-identified cases representing true positive results. That interpretation of positive test results used to identify rare diseases is a principle we all learned in medical school.

The Pain Index (FP:TP ratio) quantifies the practical consequence of this reality: for each true hemorrhage the AI correctly identifies, the radiologist must review and override this number of incorrect AI-positive flags — representing additional review time and cognitive load under the time pressure of clinical practice.

The numbers in context — and why published AI metrics feel different in practice

The headline performance statistics that accompany any AI classifier — AUC, sensitivity, specificity, and especially PPV — are typically computed on the held-out test dataset, which is usually enriched for positive cases relative to an unselected clinical population. The RSNA test set used to produce the performance table above has an "any ICH" prevalence of 14.5% (14.49% exact). An unselected emergency department CT head population has a true ICH prevalence closer to 2% — consistent with published epidemiology and with the lived experience of radiologists reading volume ED CT at busy trauma centres, past and present.

Sensitivity and specificity are intrinsic to the model and do not change with prevalence. PPV and the false-positive burden are not — they are dominated by prevalence. This is the principal reason clinicians trying out an AI in practice often feel the tool underperforms the published numbers: the metrics they read were computed on a population very different from the one in front of them. The AI is behaving exactly as advertised; the denominator has changed.

The two tables below use the same model with identical sensitivity (94%) and specificity (94.5%). Only the prevalence differs.

Test-set prevalence (14.5%) — the population used to compute the performance table above.

1,000 patients AI Positive AI Negative
True ICH (145) 136 detected 9 missed
No ICH (855) 47 false alarms 808 correctly cleared

PPV = 136 / (136 + 47) = 74% — roughly 1 in 4 AI-positive flags is a false alarm. NPV = 808 / (808 + 9) = 99.0% — a negative AI result is highly reliable. Pain Index = 47 / 136 = 0.35 — the radiologist encounters approximately 1 false positive for every 3 true detections.

Unselected ED prevalence (2%) — realistic for a busy emergency department scanning head CT for the broad mix of indications that actually drive utilisation: non-specific headache, dizziness, altered mental status, syncope, and minor trauma.

1,000 patients AI Positive AI Negative
True ICH (20) 19 detected 1 missed
No ICH (980) 54 false alarms 926 correctly cleared

PPV = 19 / (19 + 54) = 26% — roughly 3 in 4 AI-positive flags are false alarms. NPV = 926 / (926 + 1) = 99.9% — a negative AI result is extremely reliable. Pain Index = 54 / 19 = 2.9 — the radiologist reviews and overrides roughly 3 incorrect AI-positive flags for every true hemorrhage detected.

What changes, what does not

Moving from the 14.5% test-set benchmark to the 2% real-world prevalence:

  • PPV collapses from 74% to 26% — a 2.8× degradation driven entirely by the shrinking positive denominator.
  • Pain Index rises from 0.35 to 2.9 — an 8× increase in the false-positive review burden per true detection.
  • NPV actually improves (99.0% → 99.9%), because the prior probability of disease is lower to begin with. The negative AI result is, if anything, more reliable in a low-prevalence population.
  • Sensitivity, specificity, AUC, LR+, and LR− are unchanged — they are properties of the model, not the population.

This is not a model failure, a calibration problem, or a training artefact. It is the unavoidable arithmetic of Bayes' theorem applied to a rare condition. The same phenomenon applies to D-dimer testing, mammography, low-dose screening CT for lung cancer, and every other screening test in medicine. It is a principle every clinician learned in medical school — and one that is easy to forget when a vendor quotes a single PPV number.

The practical consequence is that every AI performance metric reported without an explicit prevalence is clinically incomplete. The DICOM SR generated by this pipeline records the assumed prevalence alongside every PPV/NPV calculation, and the worklist viewer recalculates them dynamically for each study's clinical context — so the radiologist always sees the statistics that match their own population, not the enriched-dataset benchmark.


When to Trust the AI — and When Not To

The statistics in this pipeline exist for one purpose: to help the radiologist know when to act on the AI result and when to look more carefully. They do not replace clinical judgment — they inform it.

The AI result should never be ignored

A positive AI flag directs attention to a specific slice in a specific study. That direction has value even when the AI is wrong. A closer second look at the flagged slice almost always resolves the question: either the hemorrhage is visible on review, or it is not. An AI positive that the radiologist cannot confirm after careful review should be rejected — and that rejection is itself a clinical act, documented and considered, not a passive dismissal.

The AI can never be 100% correct

This is not a limitation unique to AI. It is a property of any probabilistic test applied to a heterogeneous biological signal. Radiologists, experienced clinicians, and advanced imaging all operate with uncertainty. What the statistics provide is a quantified, reproducible characterisation of that uncertainty — something that is rarely available for unaided human judgment.

Reading the statistics clinically

NPV — the most powerful result in a low-prevalence population. Across the full realistic range of emergency department prevalence (2–15%), the NPV exceeds 99%. A negative AI result carries very high confidence that ICH is absent. The routine read proceeds without modification to workflow priority. In fact, NPV is highest — approaching 99.9% — at the lowest prevalence, where the prior probability of disease is smallest.

PPV — honest about the cost of false positives. Across the same 2–15% range, PPV varies dramatically: roughly 74% at the 14.5% test-set prevalence, falling to roughly 26% at an unselected 2% ED prevalence. Most AI performance tables are reported at or near test-set prevalence, which materially overstates the PPV a radiologist will see in practice. In an unselected ED population the majority of AI-positive flags will not be confirmed by the radiologist. This is not a model failure — it is the mathematical consequence of applying a powerful test to a rare condition, a principle covered in every medical school curriculum. The PPV is recalculated dynamically for the specific prevalence of each patient's clinical context, so the statistic displayed to the radiologist reflects their actual population rather than the enriched benchmark.

Pain Index — the practical workflow cost. The Pain Index (FP:TP ratio) quantifies the number of incorrect AI-positive flags the radiologist must personally review and override for each true hemorrhage detected. Each override is an additional act of scrutiny performed under clinical time pressure. The Pain Index is strongly prevalence-dependent: at 14.5% test-set prevalence it is approximately 0.35 (one false positive for every three true detections), but at an unselected 2% ED prevalence it rises to approximately 2.9 (roughly three false positives for every true detection). Whether this burden is acceptable is a local clinical judgment — but it is a burden that should be anticipated honestly, not discovered in practice after the AI has been deployed against published test-set statistics that assumed a denser positive population.

LR+ and LR− — for Bayesian reasoning. The likelihood ratios allow the radiologist or referring clinician to update their pre-test probability with the AI result, using standard Bayesian reasoning. LR+ of 17 means a positive AI result multiplies the odds of ICH by a factor of 17. LR− of 0.064 means a negative result reduces the odds to approximately 1/16 of their prior value.

The irreducible role of the radiologist

The statistics define the operating characteristics of the model as measured on held-out test data. They do not guarantee performance on any individual case. An unusual hemorrhage presentation, image quality degradation, patient motion, or a subtype underrepresented in the training data may all cause the model to underperform its aggregate metrics.

The radiologist's training, pattern recognition, and clinical context remain the final arbiter. The AI is a screening tool that ensures no study passes unremarked — not a replacement for the judgment that comes from years of training in the interpretation of CT anatomy.


The Problem with Per-Image Normalization

The standard image preprocessing idiom — normalizing each image by its own minimum and maximum pixel value — is destructive when applied to CT data:

# WRONG for CT — destroys Hounsfield calibration
tensor = (image - image.min()) / (image.max() - image.min())

CT pixel values are not arbitrary intensity values. They are Hounsfield Units (HU), a calibrated physical scale defined so that:

  • Water = 0 HU (by definition)
  • Air = −1000 HU (by definition)

Every CT scanner in clinical use is calibrated to this scale. A pixel value of 65 HU means the same thing — the density of acute blood — regardless of which scanner, which patient, or which slice produced it.

Per-image normalization maps that value to a different float every time, depending on what else is in the image. A bright slice (large hemorrhage) and a dim slice (thin subdural) will encode the same 65 HU blood pixel at completely different tensor values. The physical information is discarded.


The Solution: Fixed HU Window Encoding

Map a fixed, globally-defined HU range linearly to [0.0, 1.0]:

tensor = clip( (HU − hu_low) / (hu_high − hu_low),  0.0,  1.0 )

Values below hu_low0.0. Values above hu_high1.0. Values in between → linear. The same HU value always produces the same tensor value, across all slices and all patients.


Hounsfield Unit Reference

Tissue HU range
Air (external) −1000
Fat −100 to −50
Water / CSF 0 to 15
White matter 20 to 30
Gray matter 30 to 42
Acute ICH / blood 50 to 80
Hyperacute clot 80 to 100
Cortical bone 300 to 1000
Metal / hardware > 1000

Three Window Presets

Defined in hu_windows.py:

Wide window — WINDOW_WIDE

HU range : −1024 to 3071  (4095 HU span)

Full practical CT range. Covers air, fat, water, soft tissue, bone, and metal without saturation. The contrast between similar soft tissues is compressed to a small fraction of [0, 1].

Gray matter → blood delta: ~0.007

Use for: multi-tissue classification, bone and implant tasks.

Medium window — WINDOW_MEDIUM

HU range : −200 to 200  (400 HU span)

Soft-tissue and early-bone range. Excludes bulk air and dense bone. Captures fat, water, CSF, brain parenchyma, blood, and early cortical bone.

Gray matter → blood delta: ~0.068

Use for: brain anatomy, ICH in anatomical context.

Narrow window — WINDOW_NARROW

HU range : 48 to 90  (42 HU span)

Acute ICH detection range. Gray matter, CSF, white matter, fat, and air all map to 0.0. Only the acute blood density band occupies [0, 1].

Gray matter → blood delta: ~0.316 (5.5× wider than per-image)

Use for: maximum ICH vs. normal brain pixel contrast.


Experimental Validation

The figure below compares tensor value distributions for gray matter (HU 28–42) and acute blood (HU 50–80) pixels across 1,000 ICH-positive CT slices from the RSNA Intracranial Hemorrhage Detection dataset (n = 28.3M gray matter pixels, 5.6M blood pixels).

Normalization comparison

Scheme Gray matter (mean ± std) Acute blood (mean ± std) Δ mean GM std ratio
Per-image (min/max) 0.695 ± 0.022 0.752 ± 0.022 0.057 1.0× (baseline)
Fixed medium (−200 to 200 HU) 0.586 ± 0.009 0.653 ± 0.020 0.068 2.4× tighter
Fixed narrow (48 to 90 HU) 0.000 ± 0.000 0.316 ± 0.190 0.316 ∞ (constant)

Key observations:

  • Δ mean: the fixed narrow window achieves 5.5× greater separation between gray matter and acute blood than per-image normalization.
  • Gray matter std: per-image normalization maps the same gray matter tissue to different tensor values depending on the slice content (std 0.022). The fixed medium window reduces this variance by 2.4× (std 0.009), reflecting the physical reality that gray matter density is consistent across patients.
  • Fixed narrow: gray matter is entirely below the window floor and maps exactly to 0.0 on every slice. The blood distribution's spread (std 0.190) captures genuine biological variance in clot density and age.

Experiment code: compare_normalization.py


ICH Classification Results

To validate that the calibrated encoding provides actionable signal for deep learning, a SE-ResNeXt50 classifier was trained from random weights (no ImageNet pretraining) on the narrow-window cache (HU 48–90 → [0.0, 1.0]).

Training configuration:

  • Architecture: SE-ResNeXt50 (25.5M parameters), single-channel input
  • Loss: Focal loss (γ=2.0) with label smoothing (0.05)
  • Optimizer: AdamW, LR 3×10⁻⁴ with cosine decay, batch size 32
  • Dataset: RSNA Intracranial Hemorrhage Detection (Kaggle 2019)
    • Train+val: 544,685 slices | Test: 200,000 slices (held out)
  • Cache encoding: WINDOW_NARROW (48–90 HU), corrected fixed-window

Final test set results (200,000 held-out slices, best checkpoint epoch 25):

Class Prevalence AUC Sensitivity Specificity LR+ LR−
Epidural 0.42% 0.966 0.891 0.924 11.68 0.118
Intraparenchymal 4.85% 0.963 0.881 0.917 10.61 0.130
Intraventricular 3.52% 0.976 0.914 0.931 13.19 0.092
Subarachnoid 4.79% 0.936 0.875 0.847 5.71 0.147
Subdural 6.33% 0.957 0.878 0.901 8.90 0.135
Any ICH 14.49% 0.959 0.880 0.901 8.91 0.133
Mean 0.960

Thresholds were chosen by Youden J (maximising sensitivity + specificity) on the test set. LR+ and LR− are likelihood ratios for positive and negative results respectively — directly useful for Bayesian clinical reasoning.

Significance of random-weight initialisation: A prior run using the same architecture with ImageNet-pretrained weights but an incorrectly encoded cache (wrong HU recovery formula, 0.05–0.95 window margins) reached a best validation AUC of only 0.897 at epoch 29. The corrected encoding with random weights surpassed that result at epoch 2 (AUC 0.903) and reached 0.960 on the held-out test set. This demonstrates that the calibrated HU encoding, not the pretrained weights, is the primary driver of model performance.


Repository Structure

NewICH/
│
├── ── AI Pipeline ──────────────────────────────────────────────────────────
│
├── ich_agent.py               # Anthropic tool-use agent (agentic mode)
│                              # scan_study → series select → inference →
│                              # DICOM SR → worklist → natural-language report
│
├── ich_inference.py           # MaxViT inference engine
│                              # Loads checkpoint, runs per-slice → study-level
│                              # aggregation, returns hot slices + probabilities
│
├── ich_dicom_sr.py            # DICOM Comprehensive SR generator
│                              # Encodes AI findings, test-set metrics (AUC,
│                              # Sens, Spec, LR+, LR−, PPV, NPV, Pain Index)
│                              # Loads live metrics from test_metrics.json
│
├── ich_worklist.py            # Flask browser worklist + CT slice viewer
│                              # Serves real DICOM PNGs via /api/slice_image
│                              # Two-panel modal: CT slice + SR content
│
├── prevalence_db.py           # SQLite prevalence tracking database
│                              # Per-location, per-period prevalence queries
│                              # Feeds local prevalence back to agent
│
├── prevalence_scanner.py      # Batch archive scanner (requires --confirm)
│                              # Processes historical CT studies to seed DB
│
├── ── Demo ─────────────────────────────────────────────────────────────────
│
├── build_demo_studies.py      # Reconstructs 10 studies from RSNA slices
│                              # 5 positive (one per subtype) + 5 negative
│
├── run_demo_direct.py         # ★ Run demo without API key
│                              # Calls tools directly, templated report text
│
├── run_demo_agent.py          # Run demo via Claude agent (API key required)
│                              # Natural-language series selection + reports
│
├── demo_studies/              # Built by build_demo_studies.py
│   ├── manifest.json
│   ├── positive/
│   │   ├── subdural__<uid>/      *.dcm + ich_ai_sr.json
│   │   ├── epidural__<uid>/
│   │   ├── intraparenchymal__<uid>/
│   │   ├── intraventricular__<uid>/
│   │   └── subarachnoid__<uid>/
│   └── negative/
│       └── negative__<uid>/  (×5)
│
├── worklist.json              # Persisted worklist (auto-created)
│
├── ── Model & Training ─────────────────────────────────────────────────────
│
├── maxvit_model.py            # MaxViT-Base definition (timm-based)
├── maxvit_trainer.py          # Training loop (focal loss, cosine LR, BF16)
├── MaxVITDataset.py           # Dataset: .npz cache → (image, label) tensor
│
├── checkpoints_maxvit/
│   ├── best_maxvit_ich.pth    # Trained checkpoint (epoch 18, AUC 0.9877)
│   ├── test_metrics.json      # Held-out test metrics (200 k slices)
│   └── prevalence.db          # Local prevalence SQLite database
│
├── evaluate_maxvit_test.py    # Reproduce test metrics from cache tensors
│
├── ── Calibrated CT Preprocessing ──────────────────────────────────────────
│
├── hu_windows.py              # HUWindow dataclass, 3 presets, apply_window()
├── dicom_reader_1ch.py        # Robust DICOM → HU reader (pydicom)
├── build_medium_cache.py      # Medium-window DICOM → .npz cache builder
├── build_cache_zig.py         # High-throughput Python + Zig cache builder
├── compare_normalization.py   # Experiment: per-image vs. fixed-window
│
└── hu_tensor/                 # Zig shared library
    ├── build.zig
    └── src/hu_tensor.zig      # apply_window(), apply_three_windows() (C ABI)

Calibrated CT Preprocessing

The MaxViT classifier is trained on tensors encoded with a fixed Hounsfield Unit window rather than per-image normalization. This preserves the physical meaning of CT pixel values across all slices and patients — the key insight that allows the model to learn density-based ICH features rather than relative-brightness features. Full discussion below.


Installation

Requirements

pip install pydicom numpy pandas scipy matplotlib

Python 3.10+ recommended. The pure Python implementation has no other dependencies. The hybrid Zig implementation requires Zig 0.15.x (see below).

Zig (for hybrid implementation, AMD64 Ubuntu)

Install Zig 0.15.x via snap:

sudo snap install zig --classic --channel=0.15.x/stable

Or download a binary from ziglang.org/download and place zig on your PATH.

Build the shared library:

cd hu_tensor
zig build -Doptimize=ReleaseFast

Output: hu_tensor/zig-out/lib/libhu_tensor.so

Verify:

from build_cache_zig import _load_lib
lib = _load_lib('hu_tensor/zig-out/lib/libhu_tensor.so')
print(lib.hu_tensor_version())   # → 10000  (version 1.0.0)

Usage

Pure Python — single window

import numpy as np
from hu_windows import apply_window, WINDOW_NARROW, WINDOW_MEDIUM, WINDOW_WIDE

# hu is a float32 ndarray of Hounsfield values (from dicom_reader_1ch)
tensor = apply_window(hu, WINDOW_NARROW)   # → float16, shape (512, 512)
np.savez_compressed('slice.npz', image_norm=tensor)

Build a cache — pure Python

# Medium window (−200 to 200 HU)
python build_medium_cache.py \
    --dcm-dir  /path/to/dicom/root \
    --train-dir /path/to/cache_medium_train \
    --test-dir  /path/to/cache_medium_test \
    --splits-file ./checkpoints_1ch/data_splits.json \
    --workers 8

# Wide window (−300 to 180 HU, brain/blood window)
python build_1ch_cache.py \
    --dcm-dir    /path/to/dicom/root \
    --output-dir /path/to/cache_wide \
    --workers 8

Build a cache — hybrid Python + Zig (faster)

# Single window
python build_cache_zig.py \
    --dcm-dir /path/to/dicom/root \
    --window medium \
    --workers 8

# All three windows in one DICOM pass (most efficient)
python build_cache_zig.py \
    --dcm-dir /path/to/dicom/root \
    --window all \
    --workers 8

The --window all mode calls apply_three_windows() in the Zig library, reading each DICOM pixel array once and writing wide, medium, and narrow tensors simultaneously — one third the memory bandwidth of three separate runs.

Run the normalization experiment

python compare_normalization.py \
    --cache-dir /path/to/cache_1ch \
    --labels    /path/to/stage_2_train.csv \
    --n 1000 --workers 8

DICOM to HU Conversion

The conversion from raw DICOM pixel values to Hounsfield Units uses the metadata stored in the DICOM header, as defined by the DICOM standard:

HU = pixel_value × RescaleSlope + RescaleIntercept

RescaleSlope is 1.0 for virtually all CT scanners. RescaleIntercept is typically −1024 for modern CT scanners.

dicom_reader_1ch.py applies four validation rules to exclude invalid files:

  1. File must be readable by pydicom
  2. pixel_array must be decodable and 2-dimensional
  3. BitsAllocated must be in {8, 16, 32, 64}
  4. Resulting HU range must be plausible (rejects uncalibrated integer files, scout/localizer images, and files where the intercept was not applied)

Files lacking RescaleIntercept fall through to a scanner-convention fallback (uint16 − 1024) and are subject to rule 4 validation.


Zig Library API

The Zig shared library exports two functions via C ABI, callable from any language with a C FFI (Python ctypes, Rust, C, etc.):

// Single window: hu[n] → output[n] (float16 stored as uint16 bit patterns)
void apply_window(
    const float* hu,
    size_t n,
    float hu_low,
    float hu_high,
    uint16_t* output
);

// Three windows in one pass — 1/3 the memory bandwidth of three calls
void apply_three_windows(
    const float* hu, size_t n,
    float lo0, float hi0,    // window 0 (e.g. wide)
    float lo1, float hi1,    // window 1 (e.g. medium)
    float lo2, float hi2,    // window 2 (e.g. narrow)
    uint16_t* out0,
    uint16_t* out1,
    uint16_t* out2
);

// Returns library version as major*10000 + minor*100 + patch
uint32_t hu_tensor_version(void);

Output arrays contain float16 values stored as uint16 bit patterns. In Python: np.frombuffer(out, dtype=np.uint16).view(np.float16).


Data

Experiments use the RSNA Intracranial Hemorrhage Detection dataset (Kaggle, 2019). The dataset is not included in this repository. Labels file: stage_2_train.csv.


Credits and Acknowledgements

Authors

John B. Bramble, MD Concept, clinical domain expertise, and research direction. The principle of encoding CT pixels using fixed Hounsfield Unit windows rather than per-image normalization was developed and validated through iterative experimentation with multiple neural network architectures and window widths. This work continues a personal research interest in computer-aided diagnosis that began in the late 1980s, when Dr. Bramble developed an early CAD system for arthritis classification in C on a Commodore Amiga, working under Samuel J. Dwyer III (a principal architect of the DICOM standard) and Lawrence L. Cook at the University of Kansas Medical Center.

Claude Sonnet (Anthropic) Implementation of all source files in this repository, including the HU windowing library, DICOM reader, cache builders, MaxViT training pipeline, inference engine, DICOM SR generator, Flask worklist and CT viewer, prevalence database, archive scanner, demo runner, and this documentation. Development was conducted interactively via Claude Code in a pair-programming workflow with Dr. Bramble providing clinical direction and architectural decisions at every step.

Model architecture

MaxViT: Multi-Axis Vision Transformer Tu, Z., Talebi, H., Zhang, H., Yang, F., Milanfar, P., Bovik, A., & Li, Y. (2022). MaxViT: Multi-Axis Vision Transformer. ECCV 2022. arXiv:2204.01697

The MaxViT-Base variant is accessed via timm (PyTorch Image Models), the open-source model library maintained by Ross Wightman. github.com/huggingface/pytorch-image-models

Key packages

Package Purpose
PyTorch Deep learning framework, training and inference
timm MaxViT model definition and pretrained weights
pydicom DICOM file reading and SR generation
Flask Worklist web server
Pillow PNG encoding, HU overlay compositing
scikit-learn AUC, confusion matrix, Youden J threshold
NumPy Array operations throughout
pandas Label file handling during training

Datasets

RSNA Intracranial Hemorrhage Detection Challenge (2019) Radiological Society of North America. kaggle.com/c/rsna-intracranial-hemorrhage-detection

The model was trained and evaluated on this dataset. The full training dataset is available directly from Kaggle and is not included in this repository.

CQ500 Head CT Dataset — Demo Studies Chilamkurthy, S., Ghosh, R., Tanamala, S., Biviji, M., Campeau, N. G., Venugopal, V. K., Mahajan, V., Rao, P., & Warier, P. (2018). Deep learning algorithms for detection of critical findings in head CT scans: a retrospective study. The Lancet, 392(10162), 2388–2396. doi:10.1016/S0140-6736(18)31645-3

The seven demonstration CT studies included in demo_studies/ are drawn from the CQ500 dataset released by qure.ai under the Creative Commons CC-BY-NC-SA 4.0 licence. One study per ICH subtype (intraparenchymal, epidural, intraventricular, subdural, subarachnoid) plus two negative controls was selected by majority vote across three independent radiologist reads. Slices were subsampled to 30 per study for repository size. Full dataset available at http://headctstudy.qure.ai/dataset and via Academic Torrents.


License

MIT License. See LICENSE for details.


References

  1. Hounsfield, G.N. (1973). Computerized transverse axial scanning (tomography). British Journal of Radiology, 46(552), 1016–1022.

  2. RSNA Intracranial Hemorrhage Detection Challenge (2019). Radiological Society of North America. https://www.kaggle.com/c/rsna-intracranial-hemorrhage-detection

  3. DICOM Standard, PS 3.3 — Information Object Definitions. National Electrical Manufacturers Association (NEMA). https://www.dicomstandard.org/

  4. Flanders, A.E. et al. (2020). Construction of a Machine Learning Dataset through Collaboration: The RSNA 2019 Brain CT Hemorrhage Challenge. Radiology: Artificial Intelligence, 2(3).

  5. Tu, Z., Talebi, H., Zhang, H., Yang, F., Milanfar, P., Bovik, A., & Li, Y. (2022). MaxViT: Multi-Axis Vision Transformer. ECCV 2022. https://arxiv.org/abs/2204.01697

  6. Wightman, R. (2019). PyTorch Image Models (timm). https://github.com/huggingface/pytorch-image-models

  7. Youden, W.J. (1950). Index for rating diagnostic tests. Cancer, 3(1), 32–35. (Basis for the threshold selection method used in this pipeline.)