Low cost BLE Advertisements Repeater into Zigbee 3.0 on TLRS825x.
Use this TB-03F-KIT or TB-04-KIT ($3)
Alternative 1: TB-03F (~$1.5), lacking LEDs, USB UART, LDO. Above options are easier to set up.
Alternative 2: TS0001_TZ3000_gjrubzje
Alternative 3: Zigbee Repeater HOBEIAN
- BLE Configuration page BLE2Zigbee.html
- Initial programming (https://github.com/pvvx/TLB2Z/tree/master/pgm)
- Firmware and Zigbee OTA files (https://github.com/pvvx/TLB2Z/tree/master/fw)
- Receive BLE advertisements from up to 3 thermometer-hygrometers or motion-light sensors and translate the readings as a Zigbee end device.
- BLE advertisements are received 99.5% of the time: Zigbee polling occurs 16ms every 4 seconds. This ensures minimal reception loss from BLE devices.
- Zigbee device uses 3 endpoints. One for each BLE device.
- Zigbee TX +10dBm, BLE TX +0dBm (BLE is used for customization only).
- Zigbee OTA support.
- Support advertising BLE formats Xiaomi(Mi-Home), Qingping, BTHome v2, Custom.
- Support encrypted BLE advertising options with bindkey.
- Support BLE trigger On/Off (ATC_MiThermometer), Motion.
- Support Direct binding On/Off.
- Average consumption when operating the TB-03F-KIT module from USB (5V): 10 mA
- Connect the programmed module to the power supply
- Open BLE2Zigbee.html
- Press the button labeled "PROG" for 1 second. This action will switch the module to the BLE connection standby mode. The waiting time for BLE connection is up to 80 seconds.
- In BLE2Zigbee.html make a connection to the BLE device "B2Z-xxxxxxx".
- Enter the MAC of the thermometers and the BindKey used if necessary.
- Verify that the data is being received:
- Close BLE2Zigbee.html.
Note: On the TB-03F, for PROG, connect SWS to ground
- Enable pairing mode on the Zigbee coordinator or router.
- Press and hold the button on the module labeled "PROG" for 8 seconds. This action will reset the Zigbee bindings and settings.
- Trace the pairing of the temperature, humidity, and battery clusters. Set the desired values for "Report".
- Red LED color - reception from the 1st thermometer
- Green color LED - reception from 2nd thermometer
- Blue LED color - reception from the 3rd thermometer
- Lights up constantly if there is no pairing
- Blinks 7 times when pairing
- Blinks on "Identify" command
- Blinks briefly when waiting for BLE connection
| Endpoint | Cluster | Attribute | NN BLE device |
|---|---|---|---|
| 1 | 0x0001 Power Configuration | 0x0020 BatteryVoltage | 1 |
| 1 | 0x0001 Power Configuration | 0x0021 BatteryPercentageRemaining | 1 |
| 1 | 0x0001 Power Configuration | 0x0040 BatteryVoltage | 2 |
| 1 | 0x0001 Power Configuration | 0x0041 BatteryPercentageRemaining | 2 |
| 1 | 0x0001 Power Configuration | 0x0060 BatteryVoltage | 3 |
| 1 | 0x0001 Power Configuration | 0x0061 BatteryPercentageRemaining | 3 |
| 1 | 0x0006 On/Off | 0x0000 OnOff | 1 |
| 1 | 0x0400 Illuminance Measurement | 0x0000 MeasuredValue | 1 |
| 1 | 0x0402 Temperature Measurement | 0x0000 MeasuredValue | 1 |
| 1 | 0x0405 Relative Humidity Measurement | 0x0000 MeasuredValue | 1 |
| 2 | 0x0006 On/Off | 0x0000 OnOff | 2 |
| 2 | 0x0400 Illuminance Measurement | 0x0000 MeasuredValue | 1 |
| 2 | 0x0402 Temperature Measurement | 0x0000 MeasuredValue | 2 |
| 2 | 0x0405 Relative Humidity Measurement | 0x0000 MeasuredValue | 2 |
| 3 | 0x0006 On/Off | 0x0000 OnOff | 3 |
| 3 | 0x0400 Illuminance Measurement | 0x0000 MeasuredValue | 1 |
| 3 | 0x0402 Temperature Measurement | 0x0000 MeasuredValue | 3 |
| 3 | 0x0405 Relative Humidity Measurement | 0x0000 MeasuredValue | 3 |
- If less than 3 BLE thermometer-hygrometers are used or the thermometer-hygrometer does not transmit any parameter, then there is no need to link these clusters in the Zigbee coordinator.
- ZHA does not know how to accept 3 batteries. I.e. does not have full support for Zigbee 3.0, as it says in its advertising.
| Name | Tmin | Tmax | Change |
|---|---|---|---|
| BatteryVoltage | 360 sec | 3600 sec | 0 |
| BatteryPercentageRemaining | 360 sec | 3600 sec | 0 |
| Temperature Measurement | 30 sec | 180 sec | 10 (0.1 C) |
| Relative Humidity Measurement | 30 sec | 180 sec | 50 (0.5 %) |
- Xiaomi thermometer-hygrometers use a large data transmission interval, lasting tens of minutes. To avoid unnecessary duplicate points on the graphs, it is desirable to set appropriate (multiple) intervals in the Zigbee report.