@mattfalcone1997 mattfalcone1997 commented Jan 13, 2026

The S-Allegro benchmark includes an elbow component that must be modelled. This PR implements this by creating two elbow geometry objects and using the FormLossFromFunction1Phase component to add the minor loss per unit length. This PR does not implement heat transfer between the coaxial pipes or the ambient at this stage.

Progress

  • Elbow geometry implemented
  • Form losses implemented
  • Tests implemented

@ajdubas ajdubas merged commit 70ce12c into main Feb 23, 2026
12 of 13 checks passed
@ajdubas ajdubas deleted the coaxial-0D-elbow branch February 23, 2026 17:19