fix(ui5-date-time-picker): correct initial focus on small screens #12752
+40
−2
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Previously on initial open of the
ui5-date-time-pickerweb component on smaller screen, the focus was being set on theui5-segmented-buttoncomponent. The reason behind this was that, the button was first in the DOM tree.So now, instead of relying on automatic detection, we explicitly tell the
ui5-responsive-popoverwhich element should receive focus, by utilizing theinitialFocusproperty (in phone mode only).Before (on initial opening)
After (on initial opening)
Fixes: #11375