Skip to content

GuiyinLi/XDMyo-Dataset

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

13 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

XDMyo

Protocols

Subject

There were 21 able-bodied participants in this study. Approval of the experiment was granted by the Research Ethics Committee of Xidian University.

MYO

A Myo armband, equipped with sEMG and IMU sensors, was used to capture gestures activity. After wearing the Myo armband, each participant was required to perform a hardware calibration procedure. The procedure is to straighten the five fingers together and bend the wrist outward by 90 degrees until the MYO armband cease vibrating.

Signal

The eight-channel sEMG signals were collected at a 200-Hz sampling rate. The three-channel acceleration signals (Acc) and three-channel gyroscope signals (Gyro) were captured at a 50-Hz sampling rate.

Sequence

During the data acquisition, each type of gesture was executed in six repetitive trials. To prevent muscle fatigue, there was a 5 s rest between trials.

Participants performed each static gesture within 5 s and each dynamic gesture within 3 s.

Gesture

Folder Label Class Name Duration(s)
A 1 static Neutral 5
A 2 static Redial Deviation 5
A 3 static Flexion 5
A 4 static Ulnar Deviation 5
A 5 static Extension 5
A 6 static Hand Close 5
A 7 static Hand Open 5
A 8 dynamic Yaw Right 3
A 9 dynamic Yaw Left 3
A 10 dynamic Pitch Above 3
A 11 dynamic Pitch Below 3
A 12 dynamic Roll Exterior 3
A 13 dynamic Roll Interior 3
B 1 static OK 5
B 2 static Yeah 5
B 3 static Six 5
B 4 static Nice 5
B 5 dynamic NO 5
B 6 dynamic Come 5
B 7 dynamic Pinch 5
B 8 dynamic Raise Hand 2
B 9 dynamic Release Hand 2
B 10 dynamic Wave Hand 2

picture

0 indicates a rest phase between the same gestures, and -1 indicates a rest phase between different gestures.

Paper

The Paper had been published in IEEE Sensors Journal, and utilized Dataset A.

https://doi.org/10.1109/JSEN.2023.3327999

In XDMyo-A, the raw signal data of the 21 subjects included 1,638 (13 × 21 × 6) gestures. The dataset was partitioned into the source-dataset and the target-dataset. The source-dataset comprised data from 15 participants.

Cite

G. Li, B. Wan, K. Su, J. Huo, C. Jiang and F. Wang, "sEMG and IMU Data-Based Hand Gesture Recognition Method Using Multistream CNN With a Fine-Tuning Transfer Framework," in IEEE Sensors Journal, vol. 23, no. 24, pp. 31414-31424, 15 Dec.15, 2023, doi: 10.1109/JSEN.2023.3327999.
@ARTICLE{10305519,
  author={Li, Guiyin and Wan, Bo and Su, Kejia and Huo, Jiwang and Jiang, Changhua and Wang, Fei},
  journal={IEEE Sensors Journal},
  title={sEMG and IMU Data-Based Hand Gesture Recognition Method Using Multistream CNN With a Fine-Tuning Transfer Framework},
  year={2023},
  volume={23},
  number={24},
  pages={31414-31424},
  doi={10.1109/JSEN.2023.3327999}}

Contributors

Guiyin Li, Bo Wan, Kejia Su, Jiwang Huo, Changhua Jiang, Fei Wang

About

Upper limb gesture dataset based on surface electromyographic and inertial measurement unit.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

 
 
 

Contributors