Somewhat unwisely, OutBack seems to have inserted a new field, CCconfig_Temp_Comp_Slope into their model map between the time they first published it with the alliance and the first version available to me in their ModBus development package (AXS Port Development Package 97.zip, described in issue #273).
This field ought to be inserted after CC_Config_temp_comp_hlimt and before CC_Config_auto_restart in the current code.
| DID |
Start |
End |
Size |
R/W |
Name |
Type |
Units |
Scale Factor |
Contents |
Description |
| 64112 |
28 |
28 |
1 |
R/W |
CCconfig_Temp_Comp_Slope |
uint16 |
Mili Volts (sic) |
N/A |
Programmable |
RTS temp compensation Slope 2-6 mV per Degree C |
Additionally, the latest spec (AXS Port Development Package 105.zip) adds several fields not currently documented:
TBD
Somewhat unwisely, OutBack seems to have inserted a new field,
CCconfig_Temp_Comp_Slopeinto their model map between the time they first published it with the alliance and the first version available to me in their ModBus development package (AXS Port Development Package 97.zip, described in issue #273).This field ought to be inserted after
CC_Config_temp_comp_hlimtand beforeCC_Config_auto_restartin the current code.Additionally, the latest spec (
AXS Port Development Package 105.zip) adds several fields not currently documented:TBD