Skip to content

Latest commit

 

History

History
165 lines (139 loc) · 4.42 KB

File metadata and controls

165 lines (139 loc) · 4.42 KB

HTTP API

Inbound — Weather Station Data

The controller exposes an HTTP endpoint that Ecowitt gateways post weather data to.

GET /data/report

Health check / connectivity test.

Response: 200 OK

{ "status": "ok" }

POST /data/report

Receives weather station data from Ecowitt gateways.

Content-Type: application/x-www-form-urlencoded

The gateway sends all sensor readings as form fields. The controller captures the sender's IP address automatically and serializes the form key/value pairs into a JSON payload for internal processing.

Known form fields (non-exhaustive):

Field Description
PASSKEY Gateway passkey identifier
stationtype Station type string (e.g. GW2000A_V3.1.3)
runtime Gateway uptime in seconds
dateutc Gateway timestamp
freq Radio frequency
model Gateway model (e.g. GW2000A)
tempinf Indoor temperature (°F)
tempf Outdoor temperature (°F)
humidity Outdoor humidity (%)
humidityin Indoor humidity (%)
baromrelin Relative barometric pressure (inHg)
baromabsin Absolute barometric pressure (inHg)
winddir Wind direction (°)
windspeedmph Wind speed (mph)
windgustmph Wind gust (mph)
maxdailygust Max daily gust (mph)
solarradiation Solar radiation (W/m²)
uv UV index
rrain_piezo Rain rate piezo (in/hr)
drain_piezo Daily rain piezo (in)
wrain_piezo Weekly rain piezo (in)
mrain_piezo Monthly rain piezo (in)
yrain_piezo Yearly rain piezo (in)
soilmoisture18 Soil moisture channels (%)
soilad18 Soil admittance channels (mS)
lightning_num Lightning strike count
lightning Lightning distance
lightning_time Last lightning strike time
tempf18 Extra temperature channels (°F)
humidity18 Extra humidity channels (%)
tf_co2 CO2 sensor temperature (°F)
humi_co2 CO2 sensor humidity (%)
pm25_co2 CO2 sensor PM2.5 (µg/m³)
co2 CO2 concentration (ppm)
wh65batt, wh80batt, wh90batt, wh57batt, co2_batt, etc. Battery states
ws90cap_volt WS90 capacitor voltage

All imperial values are automatically converted to metric when controller.unit is set to "metric" (default).

Response: 200 OK, 400 Bad Request, or 500 Internal Server Error

Outbound — Gateway Subdevice Polling

The controller polls Ecowitt gateways via their local HTTP API to retrieve subdevice data. This runs as a background service on the configured ecowitt.pollingInterval.

GET http://<gateway-ip>/get_iot_device_list

Retrieves the list of connected IoT subdevices (AC1100, WFC01, WFC02).

Response structure:

{
  "command": [
    {
      "id": 12345,
      "model": 1,
      "ver": 15,
      "rfnet_state": 1,
      "battery": 4,
      "signal": 3
    }
  ]
}
Field Description
id Unique subdevice identifier
model Subdevice model: 1 = WFC01, 2 = AC1100, 3 = WFC02
ver Firmware version
rfnet_state RF network state (1 = available)
battery Battery level
signal Signal strength

POST http://<gateway-ip>/parse_quick_cmd_iot

Reads detailed subdevice data or sends commands.

Read device request:

{
  "command": [
    { "cmd": "read_device", "id": 12345, "model": 1 }
  ]
}

Response structure (varies by model):

{
  "command": [
    {
      "devicename": "WFC01",
      "nickname": "Garden Valve",
      "water_status": "0",
      "water_running": "0",
      "water_total": "1234",
      "flow_velocity": "0",
      "water_temp": "65.3",
      "wfc01batt": "4",
      "gw_rssi": "-45",
      ...
    }
  ]
}

Sensor properties are mapped through SensorBuilder (see Model/Mapping/SensorBuilder.cs) and vary per subdevice model.

Quick run command (not yet active):

{
  "command": [
    {
      "cmd": "quick_run",
      "id": 12345,
      "model": 1,
      "val": 20,
      "val_type": 1,
      "on_type": 0,
      "off_type": 0,
      "always_on": 1,
      "on_time": 0,
      "off_time": 0
    }
  ]
}

Quick stop command (not yet active):

{
  "command": [
    { "cmd": "quick_stop", "id": 12345, "model": 1 }
  ]
}