@@ -105,7 +105,7 @@ filter-seen = 5
105105# filter-non-circuit =
106106# include only messages having the specified name (partial match, alternatives and wildcard supported).
107107# HA integration: filter to some useful names for monitoring the heating circuit
108- filter-name = status|temp|humidity|yield|count|energy|power|runtime|hours|starts|mode|curve|^load$|^party$|sensor|timer
108+ filter-name = status|temp|humidity|yield|count|energy|power|runtime|hours|starts|mode|curve|^load$|^party$|sensor|timer|co2|air|flow|filter|inlet|exhaust|pressure|reset
109109# exclude messages having the specified name (partial match, alternatives and wildcard supported).
110110# filter-non-name =
111111# include only messages having the specified level (partial match, alternatives and wildcard supported).
@@ -169,34 +169,38 @@ type_switch-names = type_topic,type_class,type_state,type_sub
169169# matches at all, the variable(s) are set to the empty string.
170170# HA integration: the mapping list for (potentially) writable number entities by field type, name, message, and unit.
171171type_switch-w-number =
172- number,temperature, = temp|,°C$
173- number,temperature, = temp|,K$
172+ number,temperature, = temp|,°C$|,K$
174173 number,, = integral|,°min$
175174 number,power_factor, = power*%%
176175 number,power, = power|,kW$|,W$
177176 number,voltage, = volt|,V$
178177 number,current, = current,|,A$
179178 number,pressure, = bar$
180179 number,gas, = gas*/min$
180+ number,volume, = m³$
181+ number,volume_flow_rate, = m³/h$
181182 number,humidity, = humid*%%$
182- number,, = curve,
183+ number,, =
183184
184185# HA integration: the mapping list for numeric sensor entities by field type, name, message, and unit.
185186type_switch-number =
186187 sensor,,total_increasing = poweron|count,
187- sensor,temperature,measurement = temp|,°C$
188- sensor,temperature,measurement = temp|,K$
188+ sensor,temperature,measurement = temp|,°C$|,K$
189189 sensor,power_factor,measurement = power*%%
190190 sensor,power,measurement = power|,kW$|,W$
191191 sensor,voltage,measurement = volt|,V$
192192 sensor,current,measurement = current,|,A$
193193 sensor,,measurement = integral|,°min$
194194 sensor,energy,total_increasing = energy|,Wh$
195195 sensor,yield,total_increasing = total*,Wh$
196- sensor,,total_increasing = hours|,h$
196+ sensor,duration ,total_increasing = hours|days |,h$
197197 sensor,,total_increasing = starts*,$
198- sensor,pressure,measurement = bar$
198+ sensor,pressure,measurement = bar$|Pa$
199199 sensor,gas,measurement = gas*/min$
200+ sensor,volume,total_increasing = total*,m³$
201+ sensor,volume,measurement = m³$
202+ sensor,volume_flow_rate,measurement = m³/h$
203+ sensor,carbon_dioxide,measurement = CO2*,ppm$
200204 sensor,humidity,measurement = humid*%%$
201205 sensor,, =
202206
@@ -379,6 +383,7 @@ def_global_running-payload = %global_prefix,
379383 " device_class" :" running" %global_boolean_suffix
380384def_global_version-topic =
381385def_global_uptime-payload = %global_prefix,
386+ " device_class" :" duration" ,
382387 " state_class" :" total_increasing" ,
383388 " unit_of_measurement" :" s"
384389 }