-
Notifications
You must be signed in to change notification settings - Fork 5
Expand file tree
/
Copy pathendpipe.h
More file actions
87 lines (66 loc) · 2.62 KB
/
endpipe.h
File metadata and controls
87 lines (66 loc) · 2.62 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
/*
* This file is part of the ResOpt project.
*
* Copyright (C) 2011-2012 Aleksander O. Juell <aleksander.juell@ntnu.no>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA
*/
#ifndef ENDPIPE_H
#define ENDPIPE_H
#include "pipe.h"
#include "stream.h"
namespace ResOpt
{
/**
* @brief A top node in the Pipe network.
* @details An EndPipe is the last downstream component in the pipe network. It does not have any outlet connections. A minimum outlet pressure is specified for the EndPipe.
* The minimum outlet pressure works as a boundary condition for the pipe network, and is used by upstream parts of the network to calculate inlet pipe pressures, all
* the way down to the production wells. The inlet pressure of the pipes directly connected to production wells are compared to the producing bottomhole pressure of the well.
* If the bottomhole pressure is lower than the pipe inlet pressure, the solution is not feasible. If the bottomhole pressure is higher, the solution is considered feasible.
* It is assumed that the well may be choked back to correspond to the pipe pressure.
*
*/
class EndPipe : public Pipe
{
private:
double m_outletpressure;
Stream::units m_outlet_unit;
public:
EndPipe();
EndPipe(const EndPipe &p);
virtual ~EndPipe();
// virtual functions
virtual Pipe* clone() {return new EndPipe(*this);}
virtual void calculateInletPressure();
virtual QString description() const;
// set functions
/**
* @brief Sets the outlet pressure of the Pipe
*
* @param p
*/
void setOutletPressure(double p) {m_outletpressure = p;}
void setOutletUnit(Stream::units u) {m_outlet_unit = u;}
// get functions
/**
* @brief Returns the outlet pressure of the pipe
*
* @return double
*/
double outletPressure() const {return m_outletpressure;}
Stream::units outletUnit() const {return m_outlet_unit;}
};
} // namespace ResOpt
#endif // ENDPIPE_H