In 1.11.2 the monitor tab does not respekt more than one sACN-source for the same universe. Values might flicker.
to reproduce:
- send the same universe by two different sACN-sources (from two divices) at the same time with the same priotity
- set channe 1 on source 1 at 100% and on source 2 at 0%
- open the universe in the Monitor
problem:
The value for channel 1 is flickering.
request/solution:
At least add the merge-function from sACN per universe priority (higher priority wins or same priority are merged by HTP).
Further requests:
- List the different sources for each universe including priority.
- selecting the universe, the monitor should show the merge-result of all sources depending on priority.