Issue overview
I think it'd be less confusing if terms can be clearly separated.
So in this description, it uses the term
energy input ratio (EIR) modifierand variable calledDefrostEIRTempModFac.But based on how I'm understanding, this
DefrostEIRTempModFacis actually an "EIR" and not "EIR modifier".Because for this defrost power estimation, it is trying to calculate actual power during defrost cycle by multiplying "rated heating capacity" with "EIR" (= actual power / rated capacity).
For other curves used in coil objects, those are really "EIR modifier". As they are multiplied to "rated EIR" and not to "rated capacity".
So I thought it'd be less confusing if the documentation can say "EIR" instead of "EIR modifier".