forked from lrodriguezlujan/neurostr
-
Notifications
You must be signed in to change notification settings - Fork 2
Tilt angle definitions #27
Copy link
Copy link
Open
Labels
Description
bmihaljevic
opened on Mar 14, 2018
Issue body actions
- lmeasure tilt angle does not match neurostr one
- Different definitions
- Neurostr:
- NeuroSTR takes full parent vector
- Remote considers remote daughter whereas LM only uses daugther nodes
- Some cases > bifurcation angle. Mostly when 0 tips on either side.
- LM
- Local considers parent last compartment whereas remote considers full parent branch vector. Each only considers daughter compartments.
- LM angles too large ?
Reactions are currently unavailable