Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathHP-Temps_normalized_for_nexthink.ps1
More file actions
145 lines (117 loc) · 4.2 KB
/
HP-Temps_normalized_for_nexthink.ps1
File metadata and controls
145 lines (117 loc) · 4.2 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
<#
.SYNOPSIS:
Collects device ACPI thermal zone temperatures and outputs fixed fields for Nexthink.
.DESCRIPTION:
Queries Windows WMI class MSAcpi_ThermalZoneTemperature (root\wmi) to retrieve ACPI thermal zone
temperatures (when exposed by the device firmware/drivers).
Converts temperatures from tenths of Kelvin to Celsius, maps known ACPI zone instance names to friendly
labels (CPU, GPU, Battery, etc.), and writes a fixed set of output fields to Nexthink.
If a sensor is not available on a device, its output is set to -1.
.FUNCTIONALITY:
Data collection
.INPUTS:
None
.OUTPUTS:
- TempCPU_C
- TempGPU_C
- TempExhaust_C
- TempLocalHotspot_C
- TempBattery_C
- TempChargingCircuit_C
- TempSkin1_C
- TempSkin2_C
- TempMisc_C
- TempPCH_C
- SensorsDetected_Count
- SensorsRaw_List
.NOTES:
Context: InteractiveUser
Version: 1.0.0.0 - Initial version
Last Generated: 21 Jan 2026
#>
# Load Nexthink output writer:
Add-Type -Path "$env:NEXTHINK\RemoteActions\nxtremoteactions.dll"
# Default error handler recommended for Nexthink Remote Actions:
trap {
$host.ui.WriteErrorLine($_.ToString())
exit 1
}
# Constants / helpers:
# Fixed “not available” value for missing sensors:
$NOT_AVAILABLE = -1.0
# Raw ACPI name -> Friendly label:
$Map = @{
"ACPI\ThermalZone\CPUZ_0" = "CPU"
"ACPI\ThermalZone\GFXZ_0" = "GPU"
"ACPI\ThermalZone\EXTZ_0" = "Exhaust"
"ACPI\ThermalZone\LOCZ_0" = "LocalHotspot"
"ACPI\ThermalZone\BATZ_0" = "Battery"
"ACPI\ThermalZone\CHGZ_0" = "ChargingCircuit"
"ACPI\ThermalZone\SK1Z_0" = "Skin1"
"ACPI\ThermalZone\SK2Z_0" = "Skin2"
"ACPI\ThermalZone\MSHZ_0" = "Misc"
"ACPI\ThermalZone\PCHZ_0" = "PCH"
}
function Convert-ToCelsius {
param([int]$TenthsKelvin)
# MSAcpi_ThermalZoneTemperature is typically in tenths of Kelvin
return [math]::Round(($TenthsKelvin / 10.0) - 273.15, 1)
}
# We keep a fixed output schema by predefining all expected temperatures:
$temps = @{
CPU = $NOT_AVAILABLE
GPU = $NOT_AVAILABLE
Exhaust = $NOT_AVAILABLE
LocalHotspot = $NOT_AVAILABLE
Battery = $NOT_AVAILABLE
ChargingCircuit = $NOT_AVAILABLE
Skin1 = $NOT_AVAILABLE
Skin2 = $NOT_AVAILABLE
Misc = $NOT_AVAILABLE
PCH = $NOT_AVAILABLE
}
# Main
try {
# Query WMI (may return 0 objects on some devices):
$sensors = Get-CimInstance -Namespace "root\wmi" -ClassName MSAcpi_ThermalZoneTemperature -ErrorAction Stop
# Build a raw list for troubleshooting/visibility (kept small):
$rawNames = @()
foreach ($s in $sensors) {
$raw = [string]$s.InstanceName
$rawNames += $raw
if (-not $s.CurrentTemperature) { continue }
$c = Convert-ToCelsius -TenthsKelvin $s.CurrentTemperature
# Map raw -> friendly “key”:
if ($Map.ContainsKey($raw)) {
$friendlyKey = $Map[$raw]
# Only write into our fixed schema keys
if ($temps.ContainsKey($friendlyKey)) {
$temps[$friendlyKey] = [float]$c
}
}
}
# Write fixed outputs (float fields):
[Nxt]::WriteOutputFloat("TempCPU_C",$temps.CPU)
[Nxt]::WriteOutputFloat("TempGPU_C",$temps.GPU)
[Nxt]::WriteOutputFloat("TempExhaust_C",$temps.Exhaust)
[Nxt]::WriteOutputFloat("TempLocalHotspot_C",$temps.LocalHotspot)
[Nxt]::WriteOutputFloat("TempBattery_C",$temps.Battery)
[Nxt]::WriteOutputFloat("TempChargingCircuit_C",$temps.ChargingCircuit)
[Nxt]::WriteOutputFloat("TempSkin1_C",$temps.Skin1)
[Nxt]::WriteOutputFloat("TempSkin2_C",$temps.Skin2)
[Nxt]::WriteOutputFloat("TempMisc_C",$temps.Misc)
[Nxt]::WriteOutputFloat("TempPCH_C",$temps.PCH)
# Helpful meta outputs:
$count = 0
if ($sensors) { $count = @($sensors).Count }
[Nxt]::WriteOutputUInt32("SensorsDetected_Count", [uint32]$count)
# Keep under Nexthink string size limits: truncate defensively:
$rawList = ($rawNames | Select-Object -First 30) -join "; "
if ($rawList.Length -gt 900) { $rawList = $rawList.Substring(0, 900) }
[Nxt]::WriteOutputString("SensorsRaw_List", $rawList)
exit 0
}
catch {
$host.ui.WriteErrorLine($_.ToString())
exit 1
}